logo_trans.gif (2799 bytes)

Connecticut Industrial Gauging, Inc.

PRODUCTS

Home  |  Gauge Overview  |  Products  |  Support  |  Contact Us

System Specifications

Accuracy: At zero deviation, the accuracy will be within ±0.1% of nominal thickness, or ±0.00002" (±0.5 µm), whichever is greater
Statistical Noise: ±0.1% of nominal thickness, 90% of the time
Time Constant: 20 milliseconds or less
Deviation Range: ±30% (maximum)
Deviation Direct Output1: ±10V = ± 0.010"
Deviation Percent Output1: ±10V = ±10%

Drift:

±0.5%, or less, of nominal thickness in 8 hours, at constant ambient temperature
Notes:
  1. These are typical voltage outputs.  Scaling can be easily customized via the touch screen.  Industry standard 4 to 20 milliamp current loops are also supported and optional.
  Thickness Measurement Limits
  Aluminum Steel Copper/Nickel
  Inches Millimeters Inches Millimeters Inches Millimeters

Model

Min Max Min Max Min Max Min Max Min Max Min Max
Dataray30 0.004 0.250 0.1 6.25 n/a n/a n/a n/a n/a n/a n/a n/a
Dataray50 0.004 0.500 0.1 12.70 0.005 0.070 0.2 1.50 0.001 0.040 0.025 1.0
Dataray75 n/a n/a n/a n/a 0.005 0.250 0.2 6.25 0.001 0.150 0.025 3.8
Dataray150 n/a n/a n/a n/a 0.008 1.000 0.5 25.40 0.005 0.750 0.13 15.50